How to Set Hot Pump Non-return Valve bypass Flowrate ?

Can someone suggest the flow rate through the Restriction Orifice (RO) on a pump warm-up bypass line for the standby pump, maybe a certain percentage of the rated flow of the running pump ?

Above question could be tackled in simple or difficult way. However lets start to understand the purpose, how it is implemented and how to set the flow.

Purpose
The main purpose of the bypass line is to maintain a minimum temperature different between the pump (and associate piping ) and the pump suction fluid temperature to avoid temperature shock in the event of standby pump is started-up automatically.

How it is implemented ?
The bypass can be a fixed RO, non-return valve with hole or a globe valve. It generally install across the standby pump discharge non-return valve.

How much flow ?
The bypass flow rate should be sufficient to cater for :

i) pump and associate piping heat-up from minimum ambient to normal suction temperature within a reasonable time i.e. 2 hours
ii) heat leakage via insulation during normal operation

Generally above calculation are time consuming.

Tips
Experience based approach may be taken where setting the RO / NRV hole size as 6-8 mm or install a one (1) in globe valve.

Reference :
i) Why bypass Non-Return Valve (NRV) ?

Monday, September 29, 2008

Do i Normally Calculate Thermal Relief Load ?

Authority reserve the right to ask for calculation for thermal relief. If you or your company have done sufficient research and can be submitted to authority as supporting document, then don't waste your time to calculate it. Otherwise, you better get ready when authority ask for it...

In many event, a simple and smallest PSV i.e. DN 20 × DN 25 (NPS ¾ × NPS 1) would be sufficient for thermal relief.

Somehow if there is doubt the provided PSV is not adequate, it shall be calculated according to using Hydraulic expansion method may be used.

If the liquid being relieved potentially flash or form solids while it passes through the PSV, hydraulic expansion with two phase relief method may be used. Details refer to :
  • J. C. LEUNG, "Size Safety Relief Valves for Flashing Liquids", Chemical Engineering Progress, February 1992, pp. 70-75
  • J. C. LEUNG, and F. N. NAZARIO, "Two-Phase Flashing Flow Methods and Comparison", Journal of Loss Prevention Process Industries, Volume 3, Number 2, 1990, pp. 253-260
  • L. L. SIMPSON, "Estimate Two-Phase Flow in Safety Devices", Chemical Engineering, August 1991, pp. 98-102
Reference :
i) API Std 521 section 5.14.2., 5.14.3
ii) Thermal Relief of Non-Flashing Liquid in Pipe
iii) When Do i need a PSV for Thermal Relief on Piping ?
iv) Simple Flow Chart to Determine Requirement of Thermal Relief

When Do i need a PSV for Thermal Relief on Piping ?

Generally PSV not required for piping... however...API STD 521 2007 Addendum May 2008, section 5.14.1 (c) stated that hydraulic expansion due to solar heating on "long pipelines" shall be assessed and checked if a pressure relief valve (PSV) is required. What is "long pipelines" ? Difficult...

This section allows that a PSV may not required for thermal relief if proper administrative procedures and addition of signs stipulating the proper venting and draining procedures when shut-down and block-in are implemented. These action are acceptable and considered do not compromise the safety of personnel or equipment.

System under consideration for thermal relief consists of piping only (does not contain pressure vessels or heat exchangers), a pressure-relief device might not be required to protect piping from thermal expansion if :

  1. piping is always contains a pocket of non-condensing vapour, such that it can never become liquid-full (even it is heated and compressed); OR
  2. piping is in continuous use (i.e., not batch or semi-continuous use) and drained after being blocked-in using well supervised procedures or permits; OR
  3. fluid temperature is greater than the maximum temperature expected from solar heating (the pipe temperature direct under solar heating can reached approximately 60 °C to 70 °C, it can be as high as 85 °C for certain area i.e. Middle east) and there are no other heat sources such as heat tracing; OR
  4. the estimated pressure rise from thermal expansion is within the design limits of the equipment or piping.

Saturday, September 27, 2008

Conversion from Weight Fraction to Mole Fraction

A mixture consist of n component, e1, e2, e3,...en with molecular weight MW1, MW2, MW3, ... MWn. Each component mass are M1, M2, M3, ... Mn.

MASS FRACTION
Mass fraction of component-1, X1 = M1/MT [Eq. 1-1]
Mass fraction of component-2, X2 = M2/MT [Eq. 1-2]
Mass fraction of component-3, X3 = M3/MT [Eq. 1-3]
.
.
Mass fraction of component-i, Xi = Mi/MT [Eq. 1-i]
.
.
.
Mass fraction of component-n, Xn = Mn/MT [Eq. 1-n]
.

Total mass in mixtures, MT = M1 + M2 + M3 +...+ Mn [Eq. 2]

Number of MOLE
Component-1 number of mole, N1 = M1/MW1 [Eq. 3-1]
Component-2 number of mole, N2 = M2/MW2 [Eq. 3-2]
Component-3 number of mole, N3 = M3/MW3 [Eq. 3-3]
.
.
Component-n number of mole, Nn = Mn/MWn [Eq. 3-n]

Total number of mole,
NT = N1 + N2 + N3 +...+ Nn [Eq. 4]
NT = [M1/MW1 + M2/MW2 + M3/MW3 +...+ Mn/MWn] [Eq. 5]

MOLE FRACTION
For component-1,

Y1 = N1 / NT
Y1 = (M1/MW1) / NT

From [Eq. 1-1],
X1 = M1/MT
M1 = X1* MT
Y1 = (X1*MT/MW1) / NT

Mole Fraction of component-1,
Y1 = (M1/MW1) / NT [Eq. 6-1a]
Y1 = (X1*MT/MW1) / NT [Eq. 6-1b]

Mole Fraction of component-2,
Y2 = (M2/MW2) / NT [Eq. 6-2a]
Y2 = (X2*MT/MW2) / NT [Eq. 6-2b]

Mole Fraction of component-3,
Y3 = (M3/MW3) / NT [Eq. 6-3b]
Y3 = (X3*MT/MW3) / NT [Eq. 6-3b]
.
.
.

Mole Fraction of component-n,
Yn = (Mn/MWn) / NT [Eq. 6-na]
Yn = (Xn*MT/MWn) / NT [Eq. 6-nb]

Wednesday, September 24, 2008

PSV Capacity Correction Factor (Kw) Due to Back Pressure in Liquid Service

Capacity Correction Factor (Kw) Due to Back Pressure in Liquid Service

Conventional & Pilot Operated Pressure Relief Valves

- No special correction.

Balanced-Bellows Pressure Relief Valves

PSV Constant Back Pressure Correction Factor (Kb) for Vapor & Gas

Constant Back Pressure Correction Factor (Kb)

For Conventional Pressure Relief Valves (Vapors and Gases Only)





Note: This chart is typical and suitable for use only when the make of the valve or the actual critical flow pressure point for the vapor or gas is unknown; otherwise, the valve manufacturer should be consulted for specific data. This correction factor should be used only in the sizing of conventional (nonbalanced) pressure relief valves that have their spring setting adjusted to compensate for the superimposed back pressure. It should not be used to size balanced-type valves.


For Balanced-Bellows Pressure Relief Valve (Vapors and Gases Only)




Notes:
1. The curves above represent a compromise of the values recommended by a number of relief valve manufacturers and may be used when the make of the valve or the critical flow pressure point for the vapor or gas is unknown. When the make of the valve is known, the manufacturer should be consulted for the correction factor. These curves are for set pressures of 50 psig and above. They are limited to back pressure below critical flow pressure for a given set pressure. For set pressures below 50 psig or for subcritical flow, the manufacturer must be consulted for values of Kb.

2. See paragraph 3.3.3. in API Rp 520 Part 1

3. For 21% overpressure, Kb equals 1.0 up to PB/PS = 50%.


Related Articles

What is Capacity Correction Factor (CCF) due to Back pressure for PSV ?

What is capacity correction factor, Kb in orifice area calculation in PSV. How do we calculate this value ?

* PSV - Pressure Relief Valve

Back pressure will tend to produce a closing force on the unbalanced portion of the disc. This force may result in a reduction in lift and an associated reduction in flow capacity. Capacity correction factors, called back pressure correction factors, are provided by manufacturers to account for this reduction in flow.

For preliminary PSV sizing, figures in API RP 520 Part 1 can be referred.

Reference :
i) API RP 520 Part 1

Related Articles

Relationship Between Motor Poles Number with Speed

Display problem ? Click HERE

The following formula relates speed of the electric motor to number poles :

S = k x Hz x 60 / Number of Poles

where:

  • S = Motor speed
  • k = 2 for alternating current (AC electricity)
  • Hz = 60 for 60-Hertz electricity i.e. electricity moves (oscillates) at 60-waves per second
  • "Poles" are the positive and negative electromagnetic fields in the motor

Standard electric motor speeds at 60-Hz electricity.

  • 2-pole motor = 3,600 RPM
  • 4-pole motor = 1,800 RPM
  • 6-pole motor = 1,200 RPM
  • 8-pole motor = 900 RPM

Standard electric motor speeds at 50-Hz electricity.

  • 2-pole motor = 3,000 RPM
  • 4-pole motor = 1,500 RPM
  • 6-pole motor = 1,000 RPM
  • 8-pole motor = 750 RPM

Tuesday, September 23, 2008

Understand Reverse & Direct Acting Valves

Display problem ? Click HERE

What is direct and a reverse acting valve ?

The following clarified the different features between direct and reverse acting valve.

Direct acting valve
Air to close -- Spring to open --- Failed Open (FO)
(increasing air pressure pushes down diaphragm and extends actuator stem)



Reverse acting valve
Air to open -- Spring to close --- Failed Close (FC)
(increasing air pressure pushes up diaphragm and retracts actuator stem)




Unit Conversion in Energy in LNG Sector

Display problem ? Click HERE

Following are useful unit conversion for energy in LNG sector


1 bcm = 1000 mcm

1 mcm/d = 0.4 bcm / year

1 m3 LNG (at -161oC) = c.600 m3 gas (at 15oC)

1Mt LNG = c. 1.35 bcm gas

1 MBtu = 10 Therm = 0.293 MWh

1m3 gas = c. 11kWh

1,000 m3 = 35.31 MBtu

1 bcf/d = c. 10.34 bcm/year

1 bcf = c. 1TBtu

1 barrel oil = 5.8 MBtu

Oil parity price for gas = $17.24/MBtu when oil price = $100/barrel


Sunday, September 21, 2008

Two Suction Nozzles on Drum for Two Pumps Operation

Display problem ? Click HERE

Is it advisable to have 2 dedicated suction nozzles on a drum for 2 pumps operation? Do I have to consider the nozzle spacings to prevent suction interference ? What're the pitfall for operating 2 pumps from 2 suction nozzles?

Additional information :
  • The drum is gas liquid separator
  • Operational cases - 1 pump running, spare pump running and 2 pumps running
  • Two nozzles are 4"

Instead of having two different nozzles of 4" size you can have one single nozzle of 6" size. This will avoid no. of fittings in the suction line which will improve NPSHA. The 6" line should go up to the suction of both the pumps. Even if only one pump is running the suction velocity will be less than during both the pumps running. This will further reduce frictional head loss in the suction line improving the NPSHA.
by Dhirajkumar

If this is Gas liquid separator, then location of outlet nozzle should be kept furthest away from inlet nozzle to allow sufficient retention for bubble rising. So, please check the suitability of pump nozzle location to avoid/ minimize bubble getting into pump suction line.

Two pumps running... one pump stop instantaneously. The forward flow stop and then would create a wave return back to the vessel itself. This may create some level of liquid movement in the vessel and increase opportunity of vapor getting into second running pump... above is my guess... Make sure you have vortex breaker to minimize vapor getting into pump suction nozzle.
by JoeWong

Reference :

i) Vortex Breaker to Avoid Vapor Entrainment
ii) Estimate Minimum Submergence to Avoid Vapor Entrainment
iii) Damages by Cavitation
iv) How Pump Cavitation Sound and Looks Like ?

Different Between Shut Off Pressure & Differential Pressure for Actuator Sizing

Display problem ? Click HERE

In PCV & SDV, in that there are two terms
a. Shut off pressure
b. Maximum differential pressure for Actuator sizing

The system sequence is
Vessel A ( Oper.Pres.= 4.5 barg)
-----> PCV( Press. Drop=4 bar)
-----> SDV
-----> Vessel B (oper. Pres.=0.5 barg)

Vessel A design pressure = 12.0 barg
Vessel B design pressure = 4.0 barg
* PCV - Pressure control valve
** SDV - Shutdown Valve

Please suggest the values for the both terms for the PCV & SDV to fill.


a. Specify shut off pressure for valve tightness purpose... Worst case is design pressure-ATM = 12 bar.

b. Specify maximum differential pressure for actuator design. Large Differential Pressure across control valve, large torque required and larger the actuator (& cost). Actuator also increase with line size. In order to reduce cost, normally you put a small bypass for pressurization purpose...
by JoeWong

Reference :
i) Requirements of SDV Bypass Pressurization Line

Blowdown Valve Status After Depressuring

Display problem ? Click HERE

What should the Blowdown valve (BDV) status be after depressuring ? After reaching the isolated vessel pressure of 50% of design pressure or 100 psi (according to API Std 521), should the BDV be closed or keep in open position ? If in open position, the vessel pressure will be equalized with the flare system pressure. Any associated problem ?

BDV would be in open position (Fail safe position) to ensure evacuation of Hydrocarbon inventory... To equalize the vessel pressure with the flare system pressure would take very long. Normally, an operator would take action to initiate the closure of the BDV for last few bar.
by JoeWong